Dec 31, 2014 16. 17. General Information. ES Line/Conventional. IQ8Control C/Intelligent Addressable. FlexES Control/Intelligent Addressable. Wall Mounting/System 8010. System IQ8Control. Power Supply Units essernet. FlexES Guard. Series ES Detect (Intelligent non-addressable). 3-5. 8-9. 14-18. 36-42. 60. 66-68.
Red Essernet. En funcion del numero de equipos a conectar en la red Essernet es posible realizar dos tipos de redes. 62,5kbps. • Admite hasta 16 dispositivos de red. • Cableado mediante cable de lazo esserbus (2x0.8mm trenzado y apantallado). • Referencia tarjetas de red: 784840. 500kbps. • Admite hasta 31
Please note the restrictions underlying slot assignment for master module and the essernet®. Module (refer to Section on Micromodules). Reset. A control panel reset (warm start) may be initiated by pressing the reset button of any I/O card. V 1/ V2. LED to indicate function and operating mode of the CPU card fitted to this I/O
essernet esserbus-PLus. 2. Secure conditions: competence & responsibility. Due to our extensive product portfolio, you can realize pro- jects with us which, because of their complexity, meet the highest requirements of the fire alarm system. Our system concept is driven accordingly an thus guarantees smooth coordination
73-84. 85-89. 90. 91-104. 106-120. 110-112. 113-116. 117-120. 122-132. 134-140. Foreword. IQ8Control. Power Supply Units. LED Indicator Panel essernet. WINMAGplus. Detector Series 9000 Conventional. Large Design - ABS esserbus. Wireless Modules. 3. 8-27. 34-35. 40. 48-52. 58-67. 72. 106-109. 122-132. 134-140
Serielles essernet®-Interface. 2. FB 798819 / 06.09. Bestimmungsgema?er Gebrauch. Dieses Produkt darf nur fur die im Katalog und in der technischen Beschreibung vorgesehenen Einsatzfalle und nur in Verbindung mit den vom Hersteller empfohlenen bzw. zugelassenen Fremdgeraten und Komponenten verwendet
with an analog loop and max. 127 bus devices. C. Co nn ec to r 1. MM 1. MM 2. Without the Field device module, no connection is available for the fire department key pad and the master box. These devices can be connected to a different control panel of the essernet®. Fig. 5: Configuration FACP IQ8Control C
Permissible wire length for esserbus up to 3,500 m. • Graphically supported powerful programming tool. • Innovative alarm signalling through the new alarm generation IQ8Quad. • Supports IQ8Wireless RF technology. • Modular device structure. • Networking of up to 31 panels via essernet (500k Baud). • Up to 7 esserbus
programming tool. • Innovative alarm signalling by means of new IQ8Quad detector generation. • Supports IQ8Wireless Radio Technology and. IQ8Quad detectors with alarm devices. • A maximum of 31 control panels can be networked via essernet (500k baud). • Up to two esserbus loops, which can be extended by spurs.
RS232/RS485 serial interfaces. New ways of integration. The Multiprotocol Gateway provides the conversion of essernet data pro- tocols into standard software proto- cols for communication with overri- ding building management systems as well as devices from other manu- facturers. The basic configuration is carried out.