PFEIFFER VACUUM. TMH 521 UP and TC 600. VACUUM SERVICES, INC. X''_. TECHNICAL DATA. FLOW RATE (N2) : 500 US. COMPRESSION RATIO (NJ > 1d. 2. INLET FLANGE: DN 160 ISO-K. OUTLET FLANGE: DN 25 ISO I G 114". VENTING CONNECTION: G 118". ROTATIONAL SPEED: 50000 UMIN. WEIGHT: 13.5
Downloads of our brochures, user manuals, service documentation and other useful information from Pfeiffer Vacuum.
Connecting via a PFEIFFER vibration compensator. CAUTION The maxrmum . w Secure plug X4 on the TC 600 with a screw and tooth lock 8c. . 3.11. Connections Diagram. TC 600. TC 750. +24 VDC*/max. 200 mA (supply voltage, DCU). RS 485+l (DO/Rl). n.c.. 67. 5. GND* (mass connection, DCU). RS 485- / (DO/RI).
PFEIFFER VACUUM. TMH 621 P and TC 600. VACUUM SERVICES, INC. TECHNICAL DATA. PUMPING SPEED (N2) : 210 US. COMPRESSION RATIO (NJ > 1 X 1d. INLET FLANGE: DN 100 ISO-K. OUTLET FLANGE: DN 25 ISO I G 114". VENTING CONNECTION: G 118". ROTATIONAL SPEED: 60000 RPM. WEIGHT: 6.1
your products is missing please get in touch with your local Pfeiffer representatives or call us on the hotline shown on the back cover page. All operating instructions are also available as. PDF files. The following operating instructions are available for the range of pumps which come with DCU control units: 9. Supplementary
accordance with Section 3.3. – Only Pfeiffer Vacuum power units may be used to operate the TC 600. The use of other power units requires the prior agreement of the manufacturer and equalization with the valid specification. – The pumps may only be operated providing the ambient conditions in compliance with Protection
The safety instructions in Pfeiffer Vacuum operating manuals are the result of risk The electronic drive unit TC 400 operates designated Pfeiffer Vacuum turbo- .. of the electronic drive unit is 962. • All units connected to the bus must have differing RS485 device addresses. [P:797]. USB/RS485-converter. TC 600 / 750.
Only operate the turbopump with a prooved backing pump. • Only operate the turbopump with TC by a specified Pfeiffer Vacuum power sup- ply. The use of other power units than the intended, is only permitted after con- sultation with Pfeiffer Vacuum. • Only operate the turbopump with TC 600 in ambient conditions up to
The operator must ensure that the TC 600 is inte- grated into an emergency safety circuit. The supply voltage of the TC 600 must be interrupted when releasing the emergency safety condition. For special requirements please contact Pfeiffer. Vacuum. – The maximum permissible rotor temperature of the pump is. 80 °C. If the
Only Pfeiffer Vacuum power units may be used to operate the. TC 600. The use of other power units requires the prior agreement of the manufacturer and equalization with the valid specification. – The pumps may only be operated providing the ambient conditions in compliance with Protection Type IP 30 are observed.