GE Multilin. 750/760 Feeder Management Relay. 1-3. 1 GETTING STARTED. 1.2 USING THE RELAY. 1. 1.2.2 PANEL KEYING EXAMPLE. The following figure gives a specific example of the keypad is used to navigate through the menu structure. Specific loca- tions are referred to throughout this manual by using a path.
GE Multilin. 745 Transformer Management Relay. 1-1. 1 PRODUCT OVERVIEW. 1.1 INTRODUCTION. 1. 1 PRODUCT OVERVIEW 1.1INTRODUCTION. 1.1.1 DESCRIPTION. These instructions do not purport to cover all details or variations in equipment nor provide for every possible con- tingency to be met in connection
745 Transformer Management Relay. Multilin 745. Transformer Protection System High-speed, draw-out transformer protection and management Easy to use Transformer Protection supported by industry leading suite of software tools; Improved security for transformer energization; Accurate built-in metering functions
27 Oct 2016
software package that provides users with all of the setup and support tools needed for configuring and maintaining GE Multilin products. The setup software within. Launchpad allows configuring devices in real-time by communicating using serial,. Ethernet, or modem connections, or offline by creating setting files to be sent.
Cabling for the RS232 port is shown below for both 9 pin and 25 pin connectors. Figure 3–15: RS232 WIRING GE Multilin 745 Transformer Management Relay 3-13 . Third party equipment is available for generating the IRIG-B signal. follow instructions outlined in Section 8. However. It is not necessary to perform this test
2008 GE Multilin Incorporated. All rights reserved. GE Multilin 745 Transformer Protection System instruction manual for revision 5.11. 745 Transformer Protection System, EnerVista, EnerVista Launchpad, EnerVista 745 Setup, and FlexLogic are registered trademarks of GE Multilin Inc. The contents of this manual are the
2016 GE Multilin Inc. All rights reserved. GE Multilin Inc. 745 Transformer Protection System instruction manual for revision 5.20. 745 Transformer Protection System, EnerVista, EnerVista Launchpad, EnerVista 745 Setup, and FlexLogic are registered trademarks of GE Multilin Inc. The contents of this manual are the
GEK-106635R · 745 Instruction Manual (Enhanced faceplate) (Rev. AH), 04/25/2017, [7.6M]. For firmware version 5.23. GEK-106292D · 745 Instruction Manual (Basic faceplate) (Rev. B6), 07/10/2008, [5.3M]. For firmware version 2.80. GEK-106591 · 745 Manuale di Istruzioni (Italiano) (Rev. B2), 04/22/2004, [7.8M].
This was a nice surprise for me. Older versions of the SR-745 have a maximum voltage of 200kV. If you use newer software to set the relay, it indicates a maximum voltage of 2000.0 kV. If a voltage setting higher than the maximum is uploaded, the relay automatically divides all voltage and MVA values by a factor of 10.