Showermate Universal pumps are suitable for positive or negative head installation conditions. The pumps are designed for single shower pressure boosting applications in vented stored water systems. Inlet pressures to the pump and ambient temperatures must not exceed the values given in the technical specifications.
Fault finding, negative-head pumps (STN, SSN and STL. 2.0 CN). 8. 12. Technical data. 9. 13. Service. 11. 14. Disposal. 11. 1. Symbols used in this document. 2. General. These installation and operating instructions apply to the. Grundfos Shower Pumps, types STL, SSL, STC, STR, SSR, STP,. SSP, STN and SSN.
GRUNDFOS INSTRUCTIONS. Shower pumps. (GB) Installation and operating instructions. BE >THINK ). INNOVATE > S S S S S S S S S S S S S S S S t? pump. 22 mm servir: gate walweg. Cold-water supply to cylinder. Expansion pipe and. L?w-v?ltage pumps must be d?mestic hot-water supply connected via transformer
Your Watermill Shower Pump has been designed, manufactured and carefully tested in. England. If correctly installed and not misused, it will give many years of reliable service. To ensure satisfactory operation, we ask that you read the instructions before commencing installation. Then carry out, in sequence, each step as
APPLICATION. Showermate pumps are designed for single shower or outlet applications in vented stored water systems, inlet pressure to the pump and ambient temperature must not exceed the values given in the technical specifications. The Showermate Single pump is not suitable for boosting a single side of a dual flow.
Use 22 mm pipe to ensure an adequate flow to the pump. Connect the pump with a dedicated supply using 22 mm pipe from the cold-water storage tank. Position the cold-water outlet at least 25 mm lower than the supply to the hot-water cylinder to prevent the supply of hot water only.
After a further 15 minutes the pump will switch on automatically for a short time at a reduced pumping speed removing any water pooled in the shower area. • The pump has the ability to run dry without causing damage to the pump. • Before installation read the instructions. • Plumbing installation must comply with the
Do not allow any solder flux to come into contact with any part of this pump. If this happens, clean immediately with strong detergent, rinse and inspect surfaces for corrosion. INSTALLATION INSTRUCTIONS. FOR REGENERATIVE. MAINS SHOWER PUMP. Model: PR35D Medium pressure twin. PR50D Medium pressure
Separate from this installation manual is a pre-paid warranty card with 3 years warranty for. CT FORCE Please follow these installation instructions carefully. .. (3.0). ?". 22mm. 21mm. 3. 5.75 220 120 165 6.80 295 215 205. FORCE 15 TU. FORCE 15 ITU. 1.5 Bar Twin End. Positive and Negative. Head Shower Pump. 3.