CURLIN™ 6000 Ambulatory Infusion Pump Training Materials. If you would like hard copies of any of the training materials below please contact Customer Service: medcustomerservice@moog.com. CLINICIAN'S GUIDES Clinician Instruction Booklet (pdf) Clinician Guide CURLIN 6000 Continuous Therapy (pdf)
Your physician has prescribed the Curlin Medical ambulatory infusion pump to assist in delivering your medical treatment. Your healthcare clinician will program the pump specifically for your therapy and teach you how to use the pump in your treatment. The information in this guide will help you learn how to use the pump.
Use with Software Rev. R5(x) for Curlin Medical 4000 Series Pumps. Reorder Number 350-9009. CURLIN MEDICAL. User's Manual for use with the. 4000 Plus and 4000 CMS . Ambulatory Infusion Systems. CURLIN MEDICAL, LLC. 15751 Graham Street. Huntington Beach, CA 92649. Phone 714 893-2200 • Fax 714
Also used to provide a bolus dose when pump is running. LED INDICATORS. Green- pump is running. Yellow- standby. Red- pump in alarm status. MOOG MEDICAL DEVICES GROUP. Curlin 4000 Series™. Ambulatory Infusion Pumps. Clinician's Guide. PCA THERAPY. REFER TO USER'S MANUAL. FOR DETAILED
Fully open the door located on the top of the pump. 2. Remove IV tubing from package and locate the Blue Tubing-Guide and Yellow Flow stop. 3. Insert the Blue Tubing-Guide into the receptacle on the right side of the pump (look for the blue arrow). 4. Twist tab off Yellow Flow-Stop. 5. Insert Yellow Flow-Stop into the
Refer to the User Manual for MedLMTS instructions. 9. At Next? Press YES to continue. NOTE: Bag Volume should include overfill volume if pump priming and/or a KVO is programmed. 10. Enter Bag Volume, press YES. NOTE: To force an auto-calculation, enter any 2 of the 3 entries: Amt TBI, RATE or TIME, the unknown
Battery Life: Nominal 10 hrs at 400 ml/hr. Nominal 30 hrs at 125 ml/hr. Nominal 85 hrs at 2 ml/hr. Alarms: Infusion Complete, Air-in-line, Occlusion Upstream, Occlusion Downstream, Door Open, Set Not Installed, Unattended Pump, Replace Set, High Upstream pressure, Empty Battery. Download the User Manual
The Curlin 4000-series infusion system has been designed to meet/exceed all international standards for ruggedness and performance associated with an ambulatory medical product in normal use. In recent months, Curlin has seen an increase in the number of pumps involved in over-infusion or free-flow incidents where
Toll Free 800-253-9411. Phone 316-681-2181. Curlin Pump Instructions If your pump alerts that the batteries are low, you need to change the batteries after you turn the pump off. If you are in the middle of infusing Plane the blue} “T u1bing;.-'G'lllide": completely info;.thej'lub'lhg guide reoeplaele; .(1.,T.Ih[lsiv receptacle