Tuesday 18 September 2018 photo 3/37
|
Clamp meter vc3266l user manual
※ Download: http://xiemugovha.rutopik.ru/?dl&keyword=clamp+meter+vc3266l+user+manual&charset=utf-8&source=dayviews.com2
Figure 5 and Figure 6 Tested conductor 1000A 600V 600kW CAT. มัลติมีเตอร์ใครๆก็ใช้ได้ How to use a Multimeter. The manual is a general one for the DT3266 range of meters; hence, you read only the sections that apply.
If youʼre not sure about how to enable cookies, please refer to our. Лампу следует применять небольшой мощности: до 60 ватт. This meter can measure AC currents up to 600 A, and AC and DC voltages up to 600 V.
Mastech MS2203 User Manual - You will see a discount applied at the bottom of the shopping cart.
For temperature testing, remove test leads and slide TEMP switch to the right. Rotate the dial to your desired function. Press SEL to cycle through the parameters within the switch position. Connect to test points and read measurement on display. Inrush current SC56 allows you to get a reliable measurement of a motor's startup amp draw. You can use the inrush measurement to help diagnose a motor before it fails. The jaw light SC56 and backlight SC56 make it easier to use in any lighting condition. True RMS SC56 helps you take more accurate voltage readings on variable frequency drives. Controls O F F MFD NCV V AC V DC A AC Hz Hz % °C °F Rotate dial to the function you want to use. O F F SEL Press to cycle through parameters within a dial position. O F F Press to illuminate backlight for 60 sec O F F INRUSH Press to activate Inrush current capture mode SC56. O F F Press to manually select resolution. O F F HOLD Press to freeze both displays SC55. Do not touch exposed metal pipes, outlets, fi xtures, etc. Keep your body isolated from ground by using dry clothing, rubber shoes, rubber mats, or any approved insulating material. Inspect the test leads for damage to the insulation or exposed wire. Keep your fi ngers behind the fi nger guards on the probes while taking measurements. Use one handed testing when possible. Isolate load by disconnecting from circuit. High voltage transients can damage the meter beyond repair. Do not use during electrical storms. All voltage tests: All voltage ranges will withstand up to 600V. Do not apply more than 600VDC or AC rms. Symbols used: Caution, risk of electric shock Caution, refer to manual. Ground Double insulation Specifi cations Display: 5000 count dual display with backlight Overrange: OL or -OL is displayed Measurement rate: 3. Ranges: 500mV, 5V, 50V, 500V, 600V Resolution: 0. WARNINGS DISCONNECT AND UNPLUG TEST LEADS before opening case. TEST NCV FUNCTION ON KNOWN LIVE WIRE before using. DO NOT APPLY VOLTAGE greater than 30VAC or 60VDC to the thermocouple or the jacks when the rotary dial is on °F. Use only k-type thermocouples REMOVE THE THERMOCOUPLE when taking voltage measurements. DISCONNECT TEST LEADS when measuring temperature. DO NOT APPLY VOLTAGE TO THE JACKS when the rotary dial is on microamps. Even low voltages can cause a current overload and potentially harm the meter. O F F MFD NCV V AC V DC A AC Hz Hz % °C °F SC56 AUTO OFF TRUE RMS CAT III 600V TEMP K-TYPE 30V MAX SEL IN O F F!
Annons