Saturday 17 February 2018 photo 8/9
|
free iec 60228
=========> Download Link http://lyhers.ru/49?keyword=free-iec-60228&charset=utf-8
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
IEC 60228:2004 Standard | Conductors of insulated cables. Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch. INTERNATIONAL. STANDARD. IEC. 60228. Third edition. 2004-11. R. Commission Electrotechnique Internationale. International Electrotechnical Commission. Международная Электротехническая Комиссия. PRICE CODE. IEC 60228:2004(E). INTERNATIONAL. STANDARD. IEC. 60228. Third edition. 2004-11. This English-language version is derived from the original bilingual publication by leaving out all French-language pages. Missing page numbers correspond to the French- language pages. This is a free 5 page sample. Access the full. Info IEC-60228 Cables. September 7, 2017 | Author: Oscar Eusebio Jimenez | Category: International Electrotechnical Commission, Cable, Electrical Conductor, International Organization For Standardization, Electrical Resistance And Conductance. This is a preview - click here to buy the full publicationINTERNATIONAL STANDARD IEC 60228 Third edition 2004-11 Conductors... Iec 60228 Pdf Free Download ->->->-> http://bit.ly/2xQCfEq. Download as PDF, TXT or read online . Documents Similar To Info IEC-60228 Cables . As NZS 2211.12-2006 Safety of Laser Products Safety of Free Space Optical .OPC interfaces & source code from SISCO for power system. Minimum Resistance of Conductors in mΩ/m. CSA mm², Copper (plain), Copper (tinned), Aluminium. class 1 & 2, class 5 & 6, class 5 & 6, class 1 & 2. 0.5, 36.0, 39.0, 40.1, -. 0.75, 24.5, 26.0, 26.7, -. 1, 18.1, 19.5, 20.0, -. 1.5, 12.1, 13.3, 13.7, -. 2.5, 7.41, 7.98, 8.21, -. 4, 4.61, 4.95, 5.09, -. 6, 3.08, 3.30, 3.39, -. 10, 1.83, 1.91, 1.95. CCI Online : Conductor DC resistance calculator (IEC 60228). Stranded conductors for single core and multicore cable (IEC 60228 Class 2 Table 2) 50sqmm and 2500sqmm. Metal-coated wires are not included in this calculator.. This calculator is a free service. Use is for non-commercial purposes only and at users own. Eldtraffic Detection loop wire XLPE is a halogen-free, flexible wire for detection systems. Detection loop wire XLPE is used for the installation of detection loops in the road surface. The conductors are bare electrolytic copper with a flexible structure conforming to IEC 60228 class 5. The low moisture permeability and high. The International Electrotechnical Commission's IEC60228 standard covers the nominal cross-section areas for the conductors of various insulated cables. Standard IEC60228 covers solid and stranded copper, and aluminium and aluminium alloy conductors in cables for fixed installations and flexible copper conductors. F, stranded plain copper wire to IEC 60228 class 5. U(*), solid conductor different from plain copper. R, stranded copper conductor to IEC 60228 class 2. U, solid copper conductor to IEC 60228 class 1. Insulation or sheath. HX, cross-linked halogen free compound. Y, PVC compound. Yu, PVC, flame retardant compound. Materials. IEC 60228 Class 2 (conductor). IEC 60092-351 (insulation). IEC 60092-359 (sheath). > Flame Retardance. IEC 60332-3-22 (cat A) and IEC 60332-1-2. > Halogen Free Properties. IEC 60754-1 and -2. > Low Smoke Emission. IEC 61034-1 and -2. > Tests. IEC 60092-353. > Choice and Installation. IEC 60092-352. Standards. Construction: IEC 60502-1. Conductor: IEC 60228 class 2. Insulation: IEC 60502-1. Sheath: IEC 60092-360. Fire resistance: IEC 60331-21 (1000°C / 3 hours). Flame retardant: IEC 60332-3-22 (Cat A) and. IEC 60332-1-2. Halogen free: IEC 60754-1 /- 2. IEC 60684-2. Low smoke: IEC 61034 -1 / -2. Unarmoured, Halogen free, Low Smoke, Oil- resistant and Flame retardant. Max conductor temperature: 90°C. Voltage reating Uo/U: 0,6/1kV. CENELEC designation: Standards. Construction: IEC 60502-1. Conductor: IEC 60228 class 2. Insulation: IEC 60502-1. Sheath: IEC 60092-360. Flame retardant: IEC 60332-3-22. DIN VDE 0295 cl.5, fine-wire,. BS 6360 cl.5, IEC 60228 cl.5. Ⴠ. Ⴠ. Special PVC cable with increased heat-resistance adapted to. DIN VDE 0285-525-2-11 /. DIN EN 50525-2-11. 0,5-0,75 mm² acc. to IEC 60227/56. 1,0-2,5 mm² acc. to IEC 60227/57. The materials used in manufacture are cadmium-free and contain no silicone. Conductor : Tinned annealed stranded copper as per IEC 60228, Class 2 & Class 5; Insulation: Halogen Free ethylene polyethylene rubber as per IEC 60092-351, HF-EPR; Inner Sheath : Flame retardant thermosetting compound. Low halogen Chlorosulphonated Polyethylene rubber as per IEC 60092-359, SH; Armour. Flame-retardant ○ Halogen-free ○ Low smoke emission ○ Oil resistant (only SHF2). DESIGN: STANDARDS: IEC 60092-353, design. 1. Conductor - stranded copper conductor 1,5–10mm2. IEC 60228, class 2. - stranded copper conductor 16–150mm2. IEC 60228, class 5. - tinned stranded copper conductor on request. 2. Halogen-free. Cold-resistant. Benefits. Close-meshed braid made of galvanised steel wires protects against mechanical damage. Longer durability in harsh. Halogen-free (IEC 60754-1), no corrosive gases (IEC 60754-2), flame-retardant (IEC 60332-1-2). Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5. Finely stranded, bare copper conductors of IEC conductor class 5 acc. IEC 60228. Core insulations of power cores made of special, halogen-free, cross-linked elastomer EVI-2 acc. VDE-AR-E 2283-5. Core insulation control/ pilot core(s): Halogen-free, thermoplastic, special compound EVI-1 acc. VDE-AR-E 2283-5. class 5/IEC 60228, DIN VDE 0295 class 6/IEC 60228. cross-section mm2, no. of wires, max. wire-Ø mm, no. of wires, max. wire-Ø mm. 0.14*, ≈ 18 x 0.11. 0.25*, ≈ 14 x 0.16, ≈ 32 x 0.11. 0.34*, ≈ 7 x 0.26, ≈ 42 x 0.11. 0,50, ≈ 15/17 x 0.21, ≈ 28 x 0.16. 0,75, ≈ 23 x 0.21, ≈ 42 x 0.16. 1,00, ≈ 30 x 0.21, ≈ 56 x 0.16. Operating Voltage . . . . . . . . . . . . .0,6/1 kV. Standards applied. IEC 60092-353 – Design. IEC 60332-1 – Flame Retardant. IEC 60228 class 2 – Conductor IEC 60332-3-22 – Flame Retardant. IEC 60092-351 – Insulation. IEC 60754-1,2 – Halogen Free. IEC 60092-359 – Sheath. IEC 61034-1,2 – Low Smoke. Construction. KEC offer cables with Electrolytic Copper (Plain or Tinned) & Aluminium conductor in form of Solid, Stranded. Circular, Compacted Circular and Shaped as per IS 8130, IEC 60228 & BS EN 60228. The sector shaped conductor are manufactured with pre-spiral lay which gives compact shape to the cable with reduced dia at. TABLE 10.6 IEC cable standards Developer Standard No. Title IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC 60050-461 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354 IEC 60092-376 IEC 60227-1 IEC 60227-3 IEC 60227-6 IEC 60227-7 IEC 60228 IEC. Conductor, Stranded tinned annealed copper wires as per IEC 60228, Class 2. Insulation, B, -Halogen free EPR compound as per IEC 60092-351 - Mica/glass tape. Twisting, Two/Three Insulated cores shall be twisted together to form a pair/triad. Individual screen, (i), - Screened by copper or aluminium backed polyester. wooden drums of different sizes. • the conductors of 1,5 mm2 to 10 mm2 - class 1 may be wound in metal containers. Conductor design. • solid conductors class 1 acc. to IEC 60228. • stranded conductors class 2, 5, 6 acc. to IEC. 60228. Conductor cross section class 1 acc. to IEC 60228 class 2 acc. to IEC 60228. Weight. Flexible tinned copper core class 5 - IEC 60228. Insulation: halogen-free cross-linked compound. Colour: white. Sheath: halogen-free cross-linked compound. Standard colours: black, red. Characteristics. • Use temperature: -40°C to +90°C. • Maximum permissible core temperature: 120°C. • Maximum core temperature:. With the evolution of technology intelligent electronic devices such as sensors, inverters, measuring instruments, control and adjustment instruments have developed, which need to communicate with each other for achieving their goal. The idea of network has then become realist not only for computers but also for all. (PHF2E) Core: Tinned copper. Class5 flexible according to IEC 60228. (PHF2) Core: Plain copper. Class5 flexible according to IEC 60228. Insulation: Halogen-free fire retardant polyolefin. Colour: Black, white, blue, red, green/yellow, grey, orange. (others on request). Option: (PHF2R) Core: Plain copper. Single strand rigid. tinned copper strands, fine wires acc. to IEC 60228,. EN 60228, VDE 0295, class 5. Insulation: Besilen®. Colour code: black cores with consecutive numbers. Stranding: in layers. Wrapping: mica tape. Sheath material: P. Sheath colour: black (similar RAL 9005). Outstanding features: ▻ very good flexibility. ▻ halogen-free. 0.6 / 1 (1.2) kV. Applications. Power and control flat cables are used on festoon systems on handling equipment. Special design where halogen free and low smoke material are required (e.g. nuclear plants). Design. 1. Conductor : Flexible plain copper class 5 IEC 60228. LSHF Cable 2. Insulation : Halogen Free Compound. Applications: Lightweight halogen free ships cable medium voltage power and control cable for fixed installation in ships and offshore structures in areas that require mechanical protection or screen. Conductor: Tinned flexible compacted copper IEC 60228 class 2. Semi-conductors: Halogen free extruded compound. CONSTRUCTION. Conductor. Bare copper, stranded, IEC 60228 and EN 60228. Insulation. halogen-free, with improved fire characteristics,. BS 7629-1 and BS 5839-1. As of 10.02.. CWZ), BS EN 50200. Annex E (30 minutes), BS EN 50200 (PH120), IEC 60331-2 (120 minutes), VDE 0482-200, AREI-RGIE. Art.104-FR1. nach VDE 0295 / IEC 60228 Klasse 5. Isolierung. Polyolefin-Copolymer elektronenstrahlvernetzt. Farbe. GOST IEC 60332-1-3. >> Bunched cables GOST IEC 60332-3-22. Smoke density. GOST IEC 61034-2. Toxicity of gases. GOST 12.1.044-89. Halogen free. GOST IEC 60754-1. Corrosivity of gases. GOST IEC 60754-2. RoHS Compliant Cables and Wires Technical Information Conductor Resistance (DIN VDE 0295, IEC 60228, HD 383) from Hi-Tech Controls and Helukable. CABLE STANDARDS. TÜV listed as PV1-F. TÜV 2 PfG 1169/08.2007. IEC 60228/VDE 0295: Conductors of insulated cables. UV Resistant. HD 605/A1. Low Smoke Halogen Free. BS EN 50267-2-1, BS EN 60684-2, BS EN 61034,. BS EN 50267-2-2. Ozone Resistant. BS EN 50396. Flame Retardant. BS EN/IEC 60332-1-2. Reduction isthe gainof electrons ora decrease inoxidation state byamolecule, atom orion. wiring: The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission. InNorth America, the American WireGauge is used. wiring safety codes are intended to protect people. Q. R. S. Strand make-up according to DIN VDE 0295,. IEC 60228 and HD 383. X 17. 0,05. 14 x 0,07. 26 x 0,05. 0,08. 40 x 0,05. 0,09. 24 x 0,07*. 0,14. 18 x 0,1. 18 x 0,1. 18 x 0,1. 36 x 0,07. 72 x 0,05. 0,25. 14 x 0,15. 32 x 0,1. 32 x 0,1. 65 x 0,07. 128 x 0,05. 0,34. 7 x 0,25. 19 x 0,15. 42 x 0,1. 42 x 0,1. 88 x 0,07. 174 x 0,05. 0,38. Stranding element. Pair. Conductor category. Class 2 = stranded. Conductor material. Cu. Standardization conductor material. IEC 60228. Number of cores. 60. Material outer sheath. Flame Retardant Halogen Free Polyolefin Compound. Standardization sheath material. IEC 60092-360. Colour outer sheath. Orange. Low Smoke Halogen Free Cables LSHF. 120. 5. Construction and tests are in accordance with the recommendation of IEC publications where ever applicable.. Standards Related to Power Cables. IEC Standard. S/N. Subject. 60028. 60060-1. 60104. 60121. 60137. 60173. 60183. 60227. 60228. 60229. 60230. 60270. Being flame protected with a halogen free fire retardant system with low smoke properties these cables are designed for safety in case of fire. Construction: Conductor: Class 5 flexible tinned copper conductor according to DIN VDE 0295, BS EN/IEC 60228. Insulation: Halogen-free cross-linked compound. H07V-R (FK) is a lead free, PVC insulted house wiring cable with one circular, stranded copper conductor. The cable is designed according to HD 21.3. The conductor has resistance and number of wires according to IEC 60228 class 2. The insulation is marked "NEXANS GS SEMKO HAR area mm2". Resistance of copper conductors and design of the conductors cores according to IEC 60228 for classes 2 and 5. (1) Values according to IEC 60092-374. (2) Values according to.. at their full rated current, are laid close together in a cable bunch in such a way that there is an absence of free air circulation. Halogen free control cable designed for permanent installation inside and outside. It can be laid openly and in channels or pipes. Designed to be used when there are high demands on noise suppression. Temperature rating max 70ºC. Conductor. Stranded, annealed, tinned copper according to. IEC 60228 class 2. ture and ozone resistance. • weatherproof. • halogen free. • flexible, easy to strip and process. • high resistance to thermal pressure. • high abrasion resistance. HUBER+SUHNER. Cross section. Conductor. Core. Weight. Bending radius nom. Construction nom. dia. max. R20 IEC 60228 dia. nom. min. mm2. n x mm dia. Dimensions for class 5 flexible conductors only, according to IEC 60228 A. b). Nominal cross section + 5 % c). Largest diameter for conductors of classes I, K, M + 5 %. Mechanical Tests. All WAGO products meet the requirements of the following mechanical tests. In practical use the conductor cross sections are approx. Marking: TECNIKABEL (TO) - ITALY- (week/Year) - TKSA (Cable Type) - nº X section mm2 - 60/250 V - IEC. 60332-3-22. Construction: conductor: bare copper (IEC 60228 class 2) insulation : XLPE. Inner covering: halogen free compound (when requested by the relevant Standards) shield: tinned or plain copper braid. Construction Details - Conductor : Circular tinned stranded copper as per IEC 60228, Class 2 - Fire proof layer : Mica/Glass tape - Insulation : Halogen Free Ethylene Propylene Rubber - Cabling (with filler) - Sheath : Halogen-free thermosetting compound, SHF2. Standard Applied - Design guideline : NEK. Standard Number, BS EN 60228:2005. Title, Conductors of insulated cables. Status, Current. Publication Date, 24 March 2005. International Relationships, EN 60228 (IEC 60228:2004) AS. Amended By, Corrigendum, May 2007. Descriptors, Copper, Electrical resistance, Electric conductors, Resistance measurement,. Other non-preferred sizes are recognized for some specialized applications but are not within the scope of IEC 60228. b. The minimum number of wires for these sizes is not specified. These sizes may be constructed from 4, 5 or 6 equal segments (Milliken). c. For stranded aluminium alloy conductors. Halogen-free, fire-retardant compound. HX. : Cross-linked, halogen-free. According to IEC 60228: * Solid. (Class 1). * Stranded. (Class 2). IEC 60331 b) Fire retardance test on cable bundles. IEC 60332-3 Cat C / Cat A c) Flame retardance test on single cables or single insulated cores. IEC 60332-1 d) Smoke density test. CEI 20-37, IEC 60754, IEC 61034, CEI 20-38. Features: Acc. to CEI UNEL 00722-00725 conductor acc. to CEI 20-29, IEC 60228 insulation and sheath acc. to CEI 20-11 compound lead-free acc. to CEI 20-52 insulated cables fire resistant with elastometric compound with nominal voltage ≤ Uo/U 0,6/1 kV acc. to CEI 20-45. DESIGN: STANDARDS: IEC 60092-353, design. 1. Conductor. - stranded copper conductor. IEC 60228, class 5. 2. Insulation. - XLPE plastic. IEC 60092-351. 3. Bedding. IEC 60332-1-2 -test for single insulated wire and cable. IEC 60332-3-22 -test for bunched wires and cables, category A. Halogen-free. IEC 60754 series. HELUTHERM® 125-J/-O, extra flexible, halogen-free, temperature resistant, meter marking .... and IEC 60228 cl. 5. Ⴠ. Ⴠ. PVC single cores to DIN VDE 0812. LiYv (tinned). PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN. 60332-1-2/ IEC 60332-1 (equivalent. DIN VDE 0472 part 804 test. 6. SHIPBOARD CABLES. Specifications. Voltage. Power/Control: 600V/1000V. Instrumentation: 250 V. Conductors. Flexible metric sized bare (standard) to IEC 60228. Class 5. Insulation. 90°C Halogen free XLPE IEC 60092-351. Colour Code. Instrumentation: blue & white number coded pairs. Multi-conductor: 2C- brown,. Cross-linked halogen-free polymer mixture... Non-metallic strain relief element and rodent-protection under halogen free, flame resistant plastic sheath.... Stranded conductor structure according to DIN VDE 0295 has been defined in conformity with IEC 60228 for conductor class 2 column 1, conductor class 5 column 3. n A two layer construction with a low smoke halogen-free, flame retardant and. n IEC 60228: Conductors of Insulated Conductors, Class 5 n ASTM. of 120°C n RoHS compliant. Conductor. Soft annealed tin-coated flexible stranded copper per ASTM B-33 and. EN 60228. Insulation. Halogen-free, thermoset polyolefin. EN 60228, VDE 0295, class 5. Insulation: special A. Colour code black conductors with consecutive numbers acc. to EN 50334 green-yellow earth wire from 3 conductors. Stranding: in layers. Sheath: special A. SHF 1 compound acc. to IEC 60092-359. Sheath colour: black (RAL 9005). Outstanding features: ‰ halogen-free. X = without green-yellow earth core (OZ). Silicone Single Core Cable. Halogen Free. Construction 500V cables, fixed or flexible conductor silicone insulated with or without glass fibre braiding, halogen free to IEC 60754-2, tinned copper conductors to DIN VDE 0295 class 5 and IEC 60228 class 5, fixed –60°C to 180°C. Fire resistant. Halogen free. Fire retardant. EMC. UV-resistant. Solid conductor. IEC 60228. Yes / recommended. Permitted. No / not recommended. CONSTRUCTION. Max conductor temperature. 70. Max short circuit temperature. 250. Lowest handling temperature. -15. Insulation material. XLPE. Outersheath material. PVC. Quality XLPE Insulated Power Cable manufacturers & exporter - buy IEC 60502-1,IEC 60228 competitive price XLPE HV 8.7/15kV power cable from China manufacturer.. We will provide free relative product operation, maintenance tips and installation commissioning technical advisory service when establish cooperation.
Annons