Product, Cordis OPTEASE Vena Cava Filter Is indicated for use in the prevention of recurrent pulmonary embolism (PE) via percutaneous placement in the vena cava in the following situations: - Pulmonary thromboembolism when anticoagulants are contraindicated, - Failure of anticoagulant therapy for thromboembolitic
Removal of the OptEase retrievable vena cava filter is not feasible after extended time periods because of filter protrusion through the vena cava. Ashley DW(1), Mix JW, Christie B, Burton CG, Removal was attempted using a snare-and-sheath technique through the femoral vein. Animals with successful filter removal were
Cordis OptEasE™. Retrievable Vena Cava Filter. Cordis continues to innovate in the treatment of pulmonary embolism protection with the latest generation Retrievable . Important Information: Prior to use, refer to the “Instructions for use" supplied with these devices for indications, contraindications, side effects, suggested
28 Jul 2015 A retrospective review was performed of patients who underwent an attempted removal of a TRAPEASE or OPTEASE filter with a greater than 60-day dwell time between 2009 and 2015 at a single institution. Eleven patients within that time span were identified, and 10 were included in the review.
Before attempting retrieval of the OPTEASE® Filter from the femoral access site, verify that the filter retrieval hook is at the caudal end of the filter, i.e. caudal orientation in the IVC. The retrieval hook at the caudal end of the filter is the location for endovascular snare engagement.
6F Sheath. Ease of Use. Femoral, Jugular and. Antecubital Vein. Placement Options. Retrieval Direction. Femoral. Retrieval Period (per IFU). Can be retrieved up to and including 12 days after placement. The OPTEASE® Vena Cava Filter was designed to perform predictably and dependably. It allows you to focus on the.
It allows you to focus on the effective treatment of your patients rather than the risk of caval perforation, migration or strut embolization. With the OPTEASE® Vena Cava filter, you also have the option for retrieval within a span of 23 days.
The OPTEASE® Retrievable Vena Cava Filters are an innovative option for prevention of recurrent pulmonary embolism.
9 Aug 2010 Filters are approved for safe retrieval based on a range of days postimplantation within their Instructions for Use granted upon US Food and Drug Administration (FDA) approval. The longest labeled explantation data are as follows: Gunther Tulip (Cook Medical, Bloomington, IN), 20 days; OptEase (Cordis
19 Nov 2014