Brief Manual for JEOLJSM-6480 SEM: Starting Up. 1. Log in the SEM on FOM. Log in to the SEM computer. 2. Start JEOL program of [SEM Main Menu] on the desktop. 3. Check status of the SEM system: •. On the Column Control Panel, the [EVAC] button should be green. •. In the SEM program, the [HT] icon on the toolbar
JEOL 6700 User Manual. 05/18/2009. LOG IN to your session on the computer to the right of the microscope. Starting. Conditions. 1. Click the button and read the. Penning Gauge to ensure that the microscope is at appropriate vacuum. (10. -4. -- 10. -5. Pa). If not, consult with staff. 2. Click the Stage. Specimen Holder.
BASIC Step-by-Step Instructions for JEOL 6060LV. Version 4/13/11. General Operation. 1. Check System: Pumps running and EVAC light green (main panel near key switch)?. If not notify a staff member. 2. If the SEM software is not running, start SEM Software (SEM Main Menu icon). It takes several minutes to start,
NOTE: The purpose of this manual is for general specimen observation with the SEM. For more advanced operations or observations with accessories (e.g., backscatter electron detectors, etc.), please contact a Shared. Research Facilities staff member. You may also refer to the JEOL 7600F SEM instruction manual (pdf
analysis system (see separate operating instructions for the NORAN system). Best of all, the. JEOL JSM-6060LV scanning electron microscope is user-friendly and easy to operate. Safety. The scanning electron microscope is a relatively safe instrument.. You can do much more damage to it than it can do to you. When the
The height of the specimen must not exceed the cylinder top surface!! *If your specimen protrudes above the cylinder's top surface (or the top face of another holder), you need to measure the offset between the specimen and holder top surfaces. In order to read the offset, use the scale (see Fig. 1). This offset value is
JEOL 5800LV. SCANNING ELECTRON MICROSCOPE. OPERATOR'S MANUAL. Michael N. Spilde. Christopher Adcock. Original version: October 1999. Revised: January 2006. Department of Earth and Planetary Sciences and. Institute of Meteoritics. University of New Mexico
USING THE JEOL JSM6490LV SCANNING ELECTRON MICROSCOPE. 1. Switch on the Push and hold the Vent button on the SEM cabinet until the button lights up, bringing the specimen chamber to . Manual and check with the Lab Manager for more advanced applications such as using the Backscattered. Electron
not installed and used in accordance with the instruction manual, may cause harmful interference to the environment, especially radio communications. • This instrument must not be modified, and products other than those manufac- tured by JEOL Ltd. must not be attached to this instrument, without prior writ- ten permission.
28 Oct 2015 To help make correct judgments while imaging, the first edition of "A Guide to Scanning Microscope Observation" was published and it has since been used by a great many people. Today, after several years since the publication of the first edition, and with instrumental improvements, some parts of the