8 Aug 2010 The Reichert 7 is an auto-aligning, non-contact tonometer used to measure the intraocular pressure of the eye by delivering a very soft air puff or puffs to the eye. This User's Guide is designed as a training and reference manual for operation, maintenance, and troubleshooting. We recommend that you read
A properly functioning Pen will display “"Good". If “bAd", repeat the calibration again. If this is all unsuccessful, options include cleaning the tip (compressed air is recommended) change the batteries. Use the little probe that came with the Pen to open the battery compartment. Tech Support www.reichert.com www.tonopen.
The Tono Pen XL unit is internally calibrated, thus the instru- ment calibration should be checked only before the first use each day or in the event of unanticipated readings. Calibration must be routinely and successfully performed once daily prior to in- strument use. Calibration should also be performed whenever it.
Tono-Pen® - The one you trust in tonometry. Tono-Pen AVIA® Handheld Tonometer is always ready-to-use and calibration-free. An award-winning ergonomic design, long life battery good for thousands of measurements, and statistical confidence indicator, make it the most advanced Tono-Pen® yet. Tono-Pen AVIA builds
Procedure. The following is the suggested user-level calibration verification procedure for a Goldmann tonometer. Calibration is done at dial positions 0, 2, and 6 (equivalent to 0, 20, and 60 mmHg, respectively). Please note that this procedure is only intended to verify the accuracy of the
14 Oct 2010
Notify Reichert Customer Service immediately if any components. 6. are missing or damaged. Install the batteries in the battery compartment (see page 9). 7. Perform the Calibration Procedure (see page 11). 8. Slide a new Ocu-Film Tip Cover over the Tono-Pen XL unit's. 9. stainless steel probe tip until the Ocu-Film ridge is
Calibration verification rod; 1 measurement prism. Catalog Number: 12598; Measurement Range: 0 - 80 mmHG; Measurment Accuracy: ± 0.6 mmHg. CT210 Contact Tonometer - Brochure 339k Adobe Acrobat File. CT210 Contact Tonometer - User's Guide 782k Adobe Acrobat File. CT210 Contact Tonometer - User's Guide
6 Dec 2016 Reichert, Inc. reserves the right to make changes in the product described in this manual without notice and without incorporating those changes in any products already sold. ISO 9001/13485 Certified – Reichert products are designed and manufactured under quality processes meeting ISO 9001/13485
5.) Perform the tonometer calibration as indicated in the Instruction Manual. Note: If the tonometer does not calibrate “good", then repeat the above cleaning instructions. Do not clean more than. 3 times in a row. If the tonometer still will not calibrate, contact Reichert. Note: Always store the TONO-PEN XL tonometer with an