Manual. Analog input module AI 4xRTD/TC 2-/3-/4-wire HF (6ES7134-6JD00-0CA1). ET 200SP. 02/2014. Edition. Answers for industry. SIMATIC .. Ni 100. Ni 120. Ni 200. Ni 500. Ni 1000. Ni 0.00618 /. Ni 0.00672. Climatic2 / Standard2. Ni 1000. Ni 0.005. Thermocouple (TC). Type E, N, J, K, L, S, R,. B, T, C, U, TXK (acc. to
National Instruments Corp. 11. cRIO-9211 Operating Instructions. Measurement Accuracy for the Different Types of Thermocouples. Figures 3, 4, 5, 6, and 7 show cRIO-9211 Operating Instructions. 14 ni.com. Figure 5. Type J and N Errors. –200. 0. 200. 400. 600. 800. 1000. 1200. 0. 1. 2. 3. 4. Max over Temp Range with
Temperature measurement errors depend in part on the thermocouple type, the temperature being measured, the accuracy of the thermocouple, and the cold-junction temperature sensing accuracy. Thermocouple Input. The NI USB-TC01 supports the J, K, S, T, N, E, R, and B thermocouple types. The thermocouple input
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490. 38. Width. Height w DIN Rail 35 x 7.5 mm. 35 x 15 mm. 10 mm. 46.2 mm. 53.7 mm. CTT2.5UK/J/T/E. Dimensions & Weight. Technical Data/Ratings. Installation Instructions. Grey. U Type. J Type. T Type. G Type.
National Instruments Corp. 21 NI 9213E Operating Instructions and Specifications. Figure 6. Thermocouple Types J and N Errors. Measured Temperature (°C). Measurement Error (. °C. ) Max (High Speed), –40 to 85 °C. Max (High Res), –40 to 85 °C. Typ (High Speed), Room Temp. Typ (High Res), Room Temp. 0. 1. 3. 4. 5.
This document describes how to use the National Instruments 9211E and includes dimensions, terminal assignments, and specifications for the NI 9211E. OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E. 4-Channel Thermocouple Input Module .. Thermocouple Type J and N Errors. –200. 0. 200. 400.
25 Jan 2016 This document provides step-by-step instructions for wiring and configuring your NI DAQ device for use with a thermocouple. Before you begin using your NI DAQ hardware, you The following terminal types correspond with thermocouple measurements: TC x (+/-): Most NI thermocouple hardware refers to
NI 9214 Operating Instructions and Specifications. 28 ni.com. Table 1. Thermocouple Type J/N Measurement Accuracy (°C). –10. 0 °C. 0 °C. 1. 00 °C. 3. 00 °C. 5. 00 °C. 7. 00 °C. 9. 00 °C. 110. 0 °C. Hig h. -R esolu tion. Typical,. 23 ± 5 °C. 0.53 0.40 0.37 0.39 0.44 0.45 0.50 0.59. Max,. –20 to 70 °C. 1.70 1.24 1.00 1.16 1.44
NI 9211 Operating Instructions and Specifications. 24 ni.com. Figure 6. Thermocouple Type J and N Errors. –200. 0. 200. 400. 600. 800. 1000. 1200. 0. 1. 2. 3. 4. Max (Autozero on), –40 to 70 °C. Max (Autozero off), room temp. Typ (Autozero on), –40 to 70 °C. Measurement Error (. °C). Measured Temperature (°C)
www.ni.com. Temperature Measurements with Thermocouples: How-To Guide. 1. 2. 3. 4. 5. 6. 7. Overview. This document is part of the centralized resource portal. This tutorial provides a J-Type Thermocouple. Figure 1 illustrates a J-Type thermocouple in a candle flame that has a temperature you want to measure.