Aps-3c snow melting manual: >> http://bet.cloudz.pw/download?file=aps-3c+snow+melting+manual << (Download)
Aps-3c snow melting manual: >> http://bet.cloudz.pw/read?file=aps-3c+snow+melting+manual << (Read Online)
cit-1
eti aps-4c installation manual
sc-40c
aps-4c wiring diagram
network eti
environmental technology inc
APS-3C's DPDT output relay switches. 24 Amp heater loads or directly operates both mechanically and electrically held remote contactors. The adjustable hold-on timer provides up to 10 hours of heater operation after snowfall ceases, to complete snow/ ice melting. Independent of weather conditions, a manual heater cycle.
Snow Sensor can be paired with the GIT–1 Gutter Ice Sensor. (gutter deicing The GF-PRO uses both automatic and manual- override operator . APS-3C. Snow Melting Controller with incl. slab sensor and built-in dry contacts for EMC and remote control. Rated. 208-277V single phase. N/A. SIT-6E. Surface-mounted
Automatic Snow/Ice Melting System Control Panel. MODEL APS®–3C SNOW SWITCH®. Automatic Snow/Ice Melting System Control Panel. MODEL APS®–4C SNOW SWITCH®. Modular Snow/Ice Heater Control System. MODEL SC™–40C SATELLITE CONTACTOR. Installation and Operation Manual
This specification describes an energy efficient snow melting system for pavers and concrete and o APS-3C: 24 A o APS-4C: 40 A. (277 V single phase); 50 A (all other voltages). •. NEMA 3R enclosure. •. Integrated EUR-5A snow/ice controller. •. Up to six (6) temperature Installation and Operation Manual (H57754). 2.
controls and snow sensors: Controllers: APS-3B, APS-4, APS-3C, APS-4C, and EUR-5A. Snow Sensors: CIT-1, GIT-1, and SIT-6E, these snow sensors work the following procedure: 1. Insure that the supply light is on solid. 2. Cycle the start heat switch and to insure the system will engage the heaters in manual mode.
The adjustable hold-on timer continues heater operation for up to 10 hours after snow stops to ensure complete melting. The optional RCU–3 Remote Control Unit can be located where system operation can be conveniently observed. It duplicates many of the controls and indicators on the APS-3C front panel. It is used to
Automatic Snow/Ice Melting System Control Panel. Installation and Operation Manual. 24/7 Installation Support • Lifetime Technical Assistance • Free Design Service • www.WarmlyYours.com • (800) 875-5285. MODEL SCP-120 (APS-3C) SNOW SWITCH
In conjunction with up to six sensors residing in target zones, the microprocessor-based APS-3C provides effective, economical automatic control of snow melting applications for walkways, ramps, driveways, gutters and downspouts. Operating at either 120 volt or 208-240 volt, 50/60 Hz, the APS-3C's DPDT output relay
The ETI APS-3C provides effective, economical automatic control of snow melting applications for walkways, ramps, driveways, gutters and downspouts. Operating at either 120 volt or 208-240 volt, 50/60 Hz, the APS-3C's DPDT output relay switches 24 Amp heater loads or directly operates both mechanically and
The APS–3C Snow Switch when used with compatible sensors automatically controls snow/ice melting heaters, ensuring minimum operating costs. Typical applications include pavement, sidewalk, loading dock, roof, gutter and down spout snow/ice melting. The APS–3C is interchangeable with earlier APS–3 models.