Principle. The controller contains a temperature control where the signal can be received from one or two temperature sensors. The thermostat sensors are either placed in the cold air flow after the evaporator, in the warm air flow just before the evaporator, or both. A setting will determine how great an influence the two.
www.danfoss.com/erc. This reference manual is intended to be used primarily by OEMs for the purpose of programming. ERC 101. It may also be useful for technicians. It is not intended as a user guide for end users. ERC 101 controller. Reference manual. MAKING MODERN LIVING POSSIBLE
relay in “Manual control" mode. ON = operating situation with alarm. Compressor. Compressor. The compressor relay works in conjunction with the two thermostats. Only when both thermostats call for refrigeration will the compressor relay be operated. Running times. To prevent irregular operation, values can be set for the
Principle. The controller contains a temperature control where the signal can be received from one temperature sensor. The sensor is placed in the cold air flow after the evaporator or in the warm air flow just before the evaporator. The controller controls the defrost with either natural defrost or electric defrost. Renewed cutin
www.danfoss.com/erc. This reference manual is intended to be used primarily by OEMs for the purposes of programming ERC 102. It may also be useful for technicians. It is not intended as a user guide for end users. ERC 102 refrigeration controller. Reference manual. MAKING MODERN LIVING POSSIBLE
ERC 211. Digital controller for refrigeration and defrost, 1 relay. Rear mount (clip fixing). Drilling template. Dimensions (mm). Assembly. Wiring diagram. The ERC 211 is a smart, multipurpose refrigeration controller with temperature and . DEFROST: press for 3 seconds to stop manual defrost. The DEFROST icon is shown
Principle. The temperature in the appliance is registered by one or two temperature sensors which are located in the air flow before the evaporator (S3) or after the evaporator (S4) respectively. A setting for thermostat, alarm thermostat and display reading determines the influence the two sensor values should have for each
Principle. The controller contains a temperature control where the signal can be received from one or two temperature sensors. The thermostat sensors are either placed in the cold air flow after the evaporator, in the warm air flow just before the evaporator, or both. A setting will determine how great an influence the two.
eighth hour. Refrigeration time: Defrost is started at fixed refrigeration time inter- vals, in other words, a low need for refrigeration will "postpone" the coming defrost. Contact. Defrost is started here with a pulse signal on a digital input. Manual: An extra defrost can be activated from the control- ler's lower-most button. S5-temp.