SACE Emax 2 air circuit-breakers have been designed to manage, with maximum efficiency, all low voltage electrical installations: Performance. The SACE Emax 2 range is made up of 4 sizes: E1.2, E2.2, E4.2 and E6.2 up to 6300A, which enable switchgear of compact 3 Pushbutton for manual opening. 4 Pushbutton
ABB's Emax series of low voltage power circuit breakers embodies over half a century's experience .. Emax. Power breakers. 18. Selection guide. UL Circuit breakers. X1. E1. E2. Levels of performance. A. N-A. B-A. N-A. B-A. N-A. S-A. H-A. Frame size. A. 800. 800. 800 .. Manual mechanical close and open pushbuttons.
Abb SACE Emax 2 Pdf User Manuals. View online or download Abb SACE Emax 2 Installation, Operation And Maintenance Instructions For The Installer And The User, Installation, Operation And Maintenance Instructions.
[kA]. 42. 52,5. Sectionalizing truck. E1 CS. E2 CS. Size. (40 °C). [A]. 1250. 2000. Earthing switch with making capacity. E1 MTP. E2 MTP. Size. (40 °C). [A]. 1250. 2000. Earthing truck. E1 MT. E2 MT. Size. (40 °C). [A]. 1250. 2000. (*) The performance at 1000V is 50kA. Overview of the SACE Emax family. Fields of application
DOC. N° 1SDH001316R0002 - ECN000058721 - Rev. B. SACE Emax 2. Air Emax low voltage circuit-breakers E1.2-E2.2-E4.2-E6.2. Instructions for using Ekip Touch protection trip units and Accessories.
Emax. ABB SACE. Doc. no. Model. Apparatus. Dwg. Title. App. Resp. Off. Take over Off. Scale. Language. EN. 1SDH000460R0002. Installation, service and maintenance instructions for low voltage air circuit-breakers. • READ THIS DOCUMENT AND THE INSTRUCTION MANUAL CAREFULLY BEFORE ATTEMPTING TO.
L2234. L4681. L5179. Emax. ABB SACE. L2778. Doc. no. Model. Apparatus. Dwg. Title. App. Resp. Off. Take over Off. Scale. Language. EN. 1SDH000460R0002. Installation, service and maintenance instructions for low voltage air circuit-breakers. L5439
DOC. N° 1SDH001000R0002 - ECN000058721 - Rev. B. SACE Emax 2. Emax E2.2-E4.2-E6.2 low voltage air circuit-breakers. Installation, operation and maintenance instructions for the installer and the user
DOC. N° 1SDH001330R0002 - ECN000058721 Rev. A. SACE Emax 2. Low voltage air circuit-breakers Emax E1.2-E2.2-E4.2-E6.2. Operating instructions for the design engineer
L0849. Emax. ABB SACE. RH0287002. Installation, service and maintenance instructions for the fixed part of withdrawable version circuit-breakers. Doc. N° .. Note. The table regards fixed parts with horizontal rear terminals. Fixed part. Withdrawable 3 poles Withdrawable 4 poles kg kg. E1. 25. 28. E2. 28. 32. E3. 38. 45.