COULTER 4C PLUS cell control: abnormal low, normal and abnormal high. COULTER Then thoroughly clean the AcT diff2 analyzer following the "Clean Baths" procedure in Chapter 6 of the Operator's Guide. Reanalyze a If this does not solve the problem, call your Beckman Coulter Representative before recalibrating.
For additional information about the IQAP program, see the. IQAP Procedure Manual and Addendum for Beckman Coulter Instruments assayed for 4C-ES- Cell Control or visit our website at www.BeckmanCoulter.com. Save used reagent management cards from your AC0T diff Series reagent to use for this procedure.
CAUTION System integrity might be compromised and operational failures might occur if: r. This equipment is used in a manner other than specified. Operate the instrument as instructed in the Product. Manuals. r. You introduce software that is not authorized by Beckman Coulter into your computer. Only operate your
Procedure: AcT diff 2 Calibration. Prepared not solve the problem, call your Beckman Coulter Representative before recalibrating. 2. Do the "Clean the Baths" procedure found in Chapter 6, page 4 of the AcT diff2. Operator's Guide. 3. Calibrate only when the ambient temperature is within the system's operating range.
ABOUT THIS MANUAL. Your COULTER AC•T diff Analyzer Operator's Guide provides information on how to operate the instrument. This information is organized as follows: s Chapter 1, Routine Procedures. Contains the startup and shutdown procedures. s Chapter 2, Cell Controls. Contains information on 4C® PLUS cell
READ ALL PRODUCT MANUALS AND CONSULT WITH BECKMAN COULTER-TRAINED PERSONNEL BEFORE ATTEMPTING. TO OPERATE . CBC Panel, 2-7. CBC/DIFF Panel, 2-7. Delivery, 2-7. 2.6 SAMPLE ANALYSIS, 2-8. RBC and Platelet Analysis, 2-8. Parameter Results Obtained from the RBC/Plt Dilution, 2-9.
COULTER®AC•T diff 2™ Analyzer. Operator's Guide. PN 4237495BA (August 2010). Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 . s How to use your COULTER® AC•T diff 2™ Analyzer Manuals s About this Manual s Conventions s Graphics s Symbols s Installation Procedures s Touch Screen Icons.
27 Feb 2000 "This Service Manual contains confidential information of Beckman Coulter, Inc. and its receipt or possession does not convey any rights . WBC/BASO Dilution, 2.7-1. WBC Count, 2.7-1. BASO Count, 2.7-1. DIFF Dilution, 2.7-2. DiffPlot Development, 2.7-2. DiffPlot Regions Defined, 2.7-3. Neutrophil (Neut)
LEGAL NOTICES. Beckman Coulter, Inc. makes no representation that, upon furnishing this service manual, the holder of the manual will have .. Procedure, 4.2-3. Removing the AC•T diff 2 Analyzer's Top and Rear Center Cover, 4.2-4. Tools/Supplies Needed, 4.2-4. Removal (AC•T diff 2 Analyzer), 4.2-4. Installation (AC•T
The COULTER AcT diff2 Series Analyzer is a quantitative, automated hematology analyzer and leukocyte differential counter for In Vitro Diagnostic Use in clinical laboratories. AcT diff2 Series Analyzer parameters. Parameter. WBC - White Blood Cell or leukocyte count. LY#. Lymphocyte number. LY% Lymphocyte percent