Cut the top of the distributor tube 1/2 inch below the top of the resin tank threads. 2. Chamfer the top of the tube to prepare it for insertion into the control valve. 3. Verify that the control is equipped with the correct tank o-ring and injector type. 4. Install the control valve onto the distributor tube. 5. Grip the control valve body and
Water Master Quick Instructions · Spectrum 180/360 -3 Cycle Owners Manual · Spectrum 180 – 5 Cycle Owners Manual · Spectrum_7-360_Owners Manual · Atlantis DX Water Softener · Patriot Water Softener · Imperial Water Softener · Imperial 1.0 – 2.9 Water Softener · Erie 541 Digital Parts Replacement Guide · Erie 541
closes. If the control is a 5 cycle model manually advance the control valve to the Fast. Rinse position. If the control is a 3 cycle model, disregard step 12. Manually return the control valve back to the service position, the control will now fill the brine tank until the safety float checks close. Add the appropriate amount of salt to.
2013 Aquion, Inc. TM-EN-Ultra-Rev2013.10. Technical Manual. WATER SOFTENER . Keep this Technical Manual in a safe place and ensure that new users 541N89/J80/ULTRA. Control valve assembly. Eco. ?. 541N84/J8J/ULTRA. Control valve assembly. Eco+. ?. 7. 28/298/11. Transformer 230/24V - 50 Hz, 24VA,
22 Sep 2010 Older Erie 541 water softener circuit boards and programming guide. General: 27 As many of you know, the Erie 541 series water softener control base platform used to be of the most common systems in the USA. *T o manually cycle system, press button 1 (an arrow in the lower left corner will display.
541N SERIES. Erie Water Treatment Controls – Belgium. Page 13. Programming instructions for the Parameter Set level. In the Parameter Set level the basic configuration parameters of the unit can be programmed, depending on the specific configuration of the unit. •. Make sure that the control valve is in the service mode.
541D19 SERIES. Erie Water Treatment Controls – Belgium. Page 9. Extra features immediate regeneration: an immediate regeneration can manually be initiated by pushing in skipper tab (E) that is aligned with the day indicator (C) and turning the timer knob (K) counter clockwise, until the time of day in the time.
6 Sep 2011 Erie 541-D9/D8/180/360/Water Master pre 2010. To begin a manual cleaning on this water system, gently turn the skipper or 12 day timer wheel counter clock-wise until it stops. Hearing a clicking sound as you turn is normal. Next, turn the small white camshaft wheel clock-wise until it stops. The system